Репозиторий БГМУ
    • русский
    • English
  • English 
    • русский
    • English
  • Login
View Item 
  •   DSpace Home
  • Научное наследие БГМУ
  • Научные публикации ученых БГМУ. 2024
  • View Item
  •   DSpace Home
  • Научное наследие БГМУ
  • Научные публикации ученых БГМУ. 2024
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Nonadherence of Polyurethane Implants: a retrospective cohort study

Thumbnail
View/Open
24-30.pdf (1.825Mb)
Date
2024
Author
Batiukov, D.
Podgaiski, V.
Metadata
Show full item record

Abstract

Background Biointegration of polyurethane (PU) implants providing their stable position years after surgery ensures predictable results of breast augmentation and reconstruction almost eliminating implant factor as a cause of complications. However, in rare cases PU implants appear to be not connected to the surrounding tissues. The aim of the study was to determine the incidence of PU implant nonadherence after primary breast augmentations and augmentation mastopexies with dual plane implant position, to analyze possible causes, and to propose preventive measures and treatment possibilities of this complication. Methods The results of primary aesthetic surgeries in 333 patients with dual plane PU implant placement were analyzed. Patients were evaluated clinically, and pictures and videos taken in different periods after the surgery were compared. Particular attention was given to the changes in implant position and the appearance of asymmetries over time. Results PU implant nonadherence was found in seven patients. It can be divided into primary and secondary and may be complete or partial. Primary nonadherence was found in two cases (0.6%), and secondary in five (1.5%) cases. Possible influencing factors could have been traumatic surgical technique, seroma, hematoma, or physical trauma. The average follow-up was 33 months (1 month–15 years). Conclusion Biointegration is mandatory for the long-term predictable results with PU implants. PU implant nonadherence leads to implant malposition and may cause typical complications connected to non-PU implants. Improvements in surgical maneuvers, manufacturing process, and weight reduction of the implant may be beneficial for the stability of the results.

Description

Batiukov, D. Nonadherence of Polyurethane Implants: a retrospective cohort study / D. Batiukov, V.Podgaiski // Indian Journal of Plastic Surgery. – 2024. – Vol. 57, № 1. – P. 24–30.
URI
https://rep.bsmu.by/handle/BSMU/49591
Collections
  • Научные публикации ученых БГМУ. 2024 [2004]

Белорусский государственный медицинский университет | Библиотека БГМУ | Contact Us
 

 

ISSN 2521-6562 online

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Индексация

Google ScholarOpenDOARROAD ISSNrepositories.webometrics.info

Белорусский государственный медицинский университет | Библиотека БГМУ | Contact Us